Carrier 48fc 15 ton.

Restore set-points for thermostat and humidistat (Y/N) _____. 2021 Carrier. Manufacturer reserves the right to discontinue, or change at any time, specifications or designs …

Carrier 48fc 15 ton. Things To Know About Carrier 48fc 15 ton.

Air Conditioner Carrier 48FC Installation Instructions. Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory (2 pages) ... Page 70 FAN PERFORMANCE (cont.) Table 57 – 48TC**16 3 PHASE 15 TON HORIZONTAL SUPPLY Available External Static Pressure ...Revit 1 is BIM (Building Information Modeling) software, developed by Autodesk 2. It allows you to design with both parametric 3D modeling and 2D drafting elements. Building Information Modeling is a Computer Aided Design (CAD) paradigm that employs intelligent 3D objects to represent real physical building components such as walls and doors. 24 2 800 / 600 23000 12.0 15.0 30 2-1/2 1000 / 750 29000 12.0 15.0 36 3 1200 / 900 35400 12.5 16.0 42 3-1/2 1400 / 1050 42000 12.5 16.0 48 4 1600 / 1200 47500 12.3 16.0 60 5 1750 / 1200 57000 12.3 16.0 LEGEND dB ---Sound Levels (decibels) db—Dry Bulb SEER—Seasonal Energy Efficiency Ratio wb—Wet Bulb COP---Coefficient of Performance All WeatherMaker 3 to 6 ton units are field-convertible to horizontal airflow, which makes it easy to adjust to unex-pected jobsite complications. Comfort control Carrier’s Round Tube Plate Fin coil design helps maximize heat transfer and reliable operation. 1. Third-party trademarks and logos are property of their respective owners.Carrier Weather Series Rooftop Units* with EcoBlue ... 48/50FC – 3 to 5 Ton Models 48/50FC – 6 Ton Models 48/50GC – 3 to 5 Ton Models. Created Date: 1/22/2020 5:00:47 PM ...

48FCFM07A3A5-0A0A0 48FC = Gas Heat Packaged Rooftop F = High Heat M ... 48FCFM07A1A5-0A0A0 - 6 TON High Gas Heat 14 SEER Standard EFFICIENCY Standard STATIC 208/230 ... 48fcfm07a3a5-0a0a0_submittal; Specifications. Brand Carrier; Availability Available for Delivery; Warehouse Availability AVON, MALD; BTU Input …access it. Carrier r ooftops have high and low pressure switches, a filter drier, and 2-in. (51 mm) standard filters. Key features: Key features are: † Single cooling stage models are …Carrier 48FC 4 Ton Gas/Electric 14 SEER Packaged Rooftop Unit 208-230-3-60 MED Static. Spring 2024 Preseason is going on now. ... SEERs up to 14.0, IEER of 15.0; Gas efficiencies up to 82%; Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit;

3 TON Medium Gas Heat 14 SEER Standard EFFICIENCY Medium STATIC 208/230-3 VOLT GAS ELECTRIC RTU. ... 48FCEA04A2A5-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat A = One Stage Cooling Models ... Brand Carrier; Equipment Type Commercial Packaged Outdoor Unit; Fan Type Vane Axial; Gas Stages 1-Stage;

For example, using a R--22 gas heat, electric cooling, 6--ton unit with MCA = 28.9 and MOCP = 35, with CRPWREXH030A01 power exhaust. MCA New = 28.9 amps + 1.7 amps = 30.6 amps If the new MCA does not exceed the published MOCP, then MOCP would not change. The MOCP in this example is 35 amps, the MCA New is below 35, therefore the …Carrier rooftops have high and low pressure switches, a filter drier, and 2-in (51mm) filters standard. FEATURES . Single cooling stage models are available from 3 - 10 ton. Two cooling stage models are available from 7.5 - 15 ton. SEER up to 13.0 (up to 13.4 with ECM motor) EER’s up to 11.1 (up to 11.4 with ECM motor)is proprietary to carrier corporation and shall not be used or disclosed to others, in whole or in part, ... - 48fc packaged rooftop gas heating/electric cooling units - 14 seer 3, 4, 5 tons, 15 ieer 6 ton . project: ~untitled1 09/19/2020 prepared by: 12:13pm ...d1049ui2fjityy.cloudfront.net Replacement for. 48TCED08A2A6-0A0G0 - Gas Heat/Electric Cool Rooftop, 2-Stg 7.5T 460-3-60 Medium Fan; 48TCEM08A2A6-0A0A0 - 7.5 TON Medium Gas Heat 11 SEER Standard EFFICIENCY Medium STATIC 460-3 VOLT GAS ELECTRIC RTU

Time to clean out your attic or garage? Forget about settling for garage sale prices. These days, online auction sites and marketplaces make it easier than ever before to sell your...

NEW Direct Drive – EcoBlue™ Technology Indoor fan system uses Vane Axial fan design and electronically commutated motor with beltless design. Variable speed cooling capacity control on all models. SEER to 20.0. Gas efficiencies up to 81%. Cooling operating range up to 125 °F (52°C) and down to 0°F (-18°C)

48 50FC 8 16 01PD Carrier Nominal 10 Ton 11 2 EER Package RTU Cooling Only Two Stage 208 3 siglers mw link id 10646 ||| Product Data WeatherMaker Single Packaged Rooftop 7.5 to 15 Nominal Tons 2023 Carrier 48/50FC**08, 09, 12, 14, 16 48FC: Single-Package Gas Heating/Electric Cooling Rooftop Units 50FC: Electric Cooling Rooftop … CE - carrierenterprise.com Carrier’s WeatherMaker® 15 to 27.5 ton rooftop unit (RTU) was designed by customers for customers. With “no-strip” screw collars, handled access panels, and more, we’ve made your unit reliable and easy to install, maintain, and use. Easy to install These WeatherMaker units are designed for dedicated factory-sup- Supply Width 15.52 Return Length 37.921 Return Width 15.799 RW RL SW SL CW CL Table 5. Curb matrix Type Trane Lennox Carrier Bryant JCI/York ICP Heil Day and Nigh Goodman Daikin Older Voyager Gas/Electric GCC036-060 ZGB 036-060 48DJ 004-00, 48GJ 006 48HC 004-006, 48HE 004-006 48HJ 004-006, 48KC 004-006 48LJ 004-006, …Catalog No. 04-53480332-01 Printed in U.S.A. View and Download Carrier 48FC 08-16 Series service and maintenance instructions online. Single Package Rooftop Gas Heat/Electric Cooling Unit with Puron (R-410A) Refrigerant 7.5 to 15 Nominal Tons. 48FC 08-16 Series air conditioner pdf manual download.A short ton is equal to 2,000 pounds and a long ton is 2,240 pounds. However, there are different types of tons, depending on the country. In the United States, the ton most common...3 UNIT ARRANGEMENT AND ACCESS General Figures 1 and 2 show the general unit arrangement and access locations. Fig. 1 — Access Panels and Components, Front Fig. 2 — Typical Access Panel Locations, Rear Routine Maintenance

For example, using a R--22 gas heat, electric cooling, 6--ton unit with MCA = 28.9 and MOCP = 35, with CRPWREXH030A01 power exhaust. MCA New = 28.9 amps + 1.7 amps = 30.6 amps If the new MCA does not exceed the published MOCP, then MOCP would not change. The MOCP in this example is 35 amps, the MCA New is below 35, therefore the …8.5 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU ... 48FCEM09A3A5-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium ...View and Download Carrier WeatherMaker Puron 48FC 04 Series installation instructions manual online. ... Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge …Time to clean out your attic or garage? Forget about settling for garage sale prices. These days, online auction sites and marketplaces make it easier than ever before to sell your...10 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU. SKU ... Add to List Share. Description. 48FCEM12A3A5-0A0A0 48FC = Gas Heat Packaged Rooftop E = Medium Heat M = Single Circuit, Two Stage Cooling Model 12 = 10 Tons A = No Smoke or CO 2 ... Brand Carrier; Availability Available for …10 TON Medium Gas Heat 15 SEER Standard EFFICIENCY High STATIC 460-3 VOLT GAS ELECTRIC RTU. ... 48fc-8-14-01si; Specifications. Brand Carrier; Availability Available ... Single Package Rooftop Units Gas Heating/Electric Cooling Select 12.5 to 27.5 Ton Flue Discharge Deflector Accessory. Brand: Carrier | Category: Air Conditioner | Size: 0.33 MB. Carrier 48FC Series Pdf User Manuals. View online or download Carrier 48FC Series Installation Instructions.

Air Conditioner Carrier 48FC Installation Instructions. Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory (2 pages) ... Page 70 FAN PERFORMANCE (cont.) Table 57 – 48TC**16 3 PHASE 15 TON HORIZONTAL SUPPLY Available External Static Pressure ...

CarrierAir Conditioner Carrier 48FC Installation Instructions. Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory (2 pages) ... Page 70 FAN PERFORMANCE (cont.) Table 57 – 48TC**16 3 PHASE 15 TON HORIZONTAL SUPPLY Available External Static Pressure ...View and Download Carrier WeatherMaker Puron 48FC 04 Series installation instructions manual online. ... Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge … New direct drive - EcoBlue™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor. Single-stage cooling capacity 04-06 models, two-stage on 07-30 models. SEERs up to 14.0, IEER of 15.2. Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit. Description. 48FCFM16A3A6-0A0A0. 48FC = Gas Heat Packaged Rooftop. F = High Heat. M = Single Circuit, Two Stage Cooling Model. 16 = 15 Tons. A = No Smoke or CO 2 …7.5 TON Medium Gas Heat 11 SEER Standard EFFICIENCY Medium STATIC 208/230-3 VOLT GAS ELECTRIC RTU. SKU 48TCEM08A2A5-0A0A0. ... Brand Carrier; BTU Input 224000; Equipment Type Commercial Packaged Outdoor Unit; Fan Type Centrifugal; Frame Size 56; Gas Stages 2-Stage; Heat Size Medium Gas Heat; LEER 12.7;12.5 TON High Gas Heat 15 SEER Standard EFFICIENCY High STATIC 208/230-3 VOLT GAS ELECTRIC RTU. ... 48fc-8-14-01si; Specifications. Brand Carrier; BTU Input 250000;Gas Heating/Electric Cooling Models (48FC) 1. Rated and certified under ARI Standard 210/240 3-5 ton or 340/360 6-ton, as appropriate. 2. Ratings are based on: » Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F (35°C) db outdoor air temp. 3.IEERs up to 15.2. All models are capable of either vertical or horizontal airflow. The Carrier rooftop unit (RTU) was designed by customers for customers. With “no-strip” screw collars, handled access panels, and more, the unit is easy to install, easy to maintain, and easy to use. Your new 3 to 6 ton Carrier WeatherMaker rooftop unit

Carrier contractors are ready to help you create your ideal home environment. Find an Expertkeyboard_arrow_right. Explore HVAC Systems & Products. Learn about our innovative products and how they can help improve your comfort. Browse Productskeyboard_arrow_right. Learn Heating & Cooling Basics.

48 50FC 8 16 01PD Carrier Nominal 10 Ton 11 2 EER Package RTU Cooling Only Two Stage 208 3 siglers mw link id 10646 ||| Product Data WeatherMaker Single Packaged Rooftop 7.5 to 15 Nominal Tons 2023 Carrier 48/50FC**08, 09, 12, 14, 16 48FC: Single-Package Gas Heating/Electric Cooling Rooftop Units 50FC: Electric Cooling Rooftop …

GAS HEATING/ELECTRIC COOLING ROOFTOP UNIT WITH PURON® REFRIGERANT COMMERCIAL ROOFTOP EQUIPMENT. GENERAL LIMITED WARRANTY STATEMENT – Carrier Corporation warrants this product against failure due to defects in material and workmanship under normal use and service, subject to the conditions, exclusions and time periods set forth herein. 6 TON High Gas Heat 14 SEER Standard EFFICIENCY Medium STATIC 460-3 VOLT GAS ELECTRIC RTU ... 48FCFM07A2A6-0A0A0 48FC = Gas Heat Packaged Rooftop F = High Heat M ... cable-ready for connection to the Carrier Comfort Network (CCN), Carrier i--Vu , and Third Party BACnet* building management systems. The control provides high-speed communications for remote monitoring via the Internet. Multiple units can be linked together (and to other Direct Digital Control (DDC) equipped units) using a 3-wire communication ... Page 41: Rtu Open Controller (Factory Option) Completing Return Air Smoke Sensor Installation RTU Open Controller (Factory Option) Unscrew the two screws holding the Return Air Smoke For details on operating 48FC**04-07 units equipped with the Detector assembly. See Fig. 53, Step 1. View and Download Carrier 48FC Series controls, start-up, operation and troubleshooting online. Single Package Rooftop Units with SystemVu Controls Version 1.X and Puronr (R-410A) Refrigerant. 48FC Series air …These units meet the upcoming DOE-2023 (Department of Energy) and ASHRAE (American Society of Heating, Refrigerating, and Air-Conditioning Engineers) 90.1 IEER …Build performance, reliability and flexibility into your custom air handler solution. Carrier’s Aero® air handlers provide advanced technology and custom features in streamlined, easy-to-install packages. Indoor and outdoor air handling units are available to handle a wide variety of applications. 5 Product (s)S Two cooling stage models are available from 7.5 -- 15 ton. S SEER up to 13.0. S EER’s up to 11.1. S IEER’s up to 11.8. S Up to 28% lighter than similar industry units. Lighter rooftops make easier replacement jobs. S Utility connections are the same because 3 -- 12.5 ton units fit on existing Carrier rooftop curbs. This saves time andElectric heating and electric cooling with up to 15.5 SEER2 for enhanced energy savings with enhanced comfort features. 4.5 out of 5 stars. 4.5 out of 5 stars. 4.5 out of 5 stars. 81 Reviews. 5 Star. 65% . 4 Star. 21% . 3 Star. 9% . ... Your Carrier expert will recommend the appropriate model to fit your needs. Warranty. 10-year parts limited ...View and Download Carrier WeatherMaker Puron 48FC 04 Series installation instructions manual online. ... Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge …CE - carrierenterprise.com

A short ton is equal to 2,000 pounds and a long ton is 2,240 pounds. However, there are different types of tons, depending on the country. In the United States, the ton most common...Lighter units make easy replacement. Most of Carrier’s 3--12.5 ton 48HC rooftops fit on existing Carrier curbs dating back to 1989. Also, our large control box gives you room to work and room to mount Carrier accessory controls. Easy to maintain: Easy access handles by Carrier provide quick and easy access to all normally serviced components.Catalog No. 04-53480332-01 Printed in U.S.A. View and Download Carrier 48FC 08-16 Series service and maintenance instructions online. Single Package Rooftop Gas Heat/Electric Cooling Unit with Puron (R-410A) Refrigerant 7.5 to 15 Nominal Tons. 48FC 08-16 Series air conditioner pdf manual download.Fig. 1 — 48FC 04-07 Model Number Nomenclature Model Series — WeatherMaker® FC = 14.0 SEER Standard Efficiency, sizes 04-06 13.4 SEER2 Standard Efficiency, sizes 04-06 15.0 IEER Standard Efficiency, size 07 Unit Heat Type 48 = Gas Heat Packaged Rooftop Cooling Tons 04 = 3 tons 05 = 4 tons 06 = 5 tons 07 = 6 tons Heat Size D = Low Gas HeatInstagram:https://instagram. craigslist cars for sale in fresno californiahurlburt thrift shopclear creek az weathercrestwood village 6 manchester nj carrier 48fc ton › ... Carrier 48FCFM07A3A6-0A0A0 TON High Gas Heat 14 SEER Standard EFFICIENCY High STATIC 460 VOLT GAS ELECTRIC RTU DCNE. 4.8 (195) · USD 30.8 · In stock. Description. The MRCOOL DIYM218HPC00C07 is a dual zone ceiling cassette mini split that offers 18,000 BTUs of cooling Free Shop now at.View and Download Carrier WeatherMaker Puron 48FC 04 Series installation instructions manual online. ... Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge … indian sweets in seattlejeffy breaks his helmet Up to 15.8 SEER, 13.0 IEER, 12,1 EER, 8.2 HSPF, and 3.5 COP. Cooling operating range up to 125°F (52°C) and down to 30°F (-1°C) Exclusive non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain. Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt ...These units meet the upcoming DOE-2023 (Department of Energy) and ASHRAE (American Society of Heating, Refrigerating, and Air-Conditioning Engineers) 90.1 IEER … kenny chesney svg Product Summary. WeatherMaker Gas Heat/Electric Cooling Packaged Rooftop 3 to 15 Nominal Tons. Features and Benefits: Single cooling stage models are available from 3 -- 10 ton. Two cooling stage models are available from 7.5 -- 15 ton. SEER up to 13.0. (up to 13.4 with ECM motor) EER's up to 11.1. (up to 11.4 with ECM motor)Carrier gas heat/electric cooling packaged rooftop 3 to 15 nominal tons (101 pages) ... Air Conditioner Carrier 48FC Installation Instructions. Single package rooftop units gas heating/electric cooling select 12.5 to 27.5 ton flue discharge deflector accessory (2 pages) ...